Описана настройка RAID массивов на контроллере Adaptec из консоли через arcconf
Где взять пакет arcconfПример как найти
Вывод всей конфигурации (по контроллеру с номером 1)
arcconf getconfig 1
Вывод конфигурации - Физические Диски
arcconf getconfig 1 PD arcconf getconfig 1 PD |grep -E "Device|Channel|Vendor|Model|Total|SSD"
Physical Device information
Device #0
Device is a Hard drive
Reported Channel,Device(T:L) : 0,4(4:0)
Reported Location : Connector 1, Device 0
Vendor :
Model : KINGSTON SV300S3
Total Size : 57241 MB
SSD : Yes
Device #1
Device is a Hard drive
Reported Channel,Device(T:L) : 0,5(5:0)
Reported Location : Connector 1, Device 1
Vendor :
Model : KINGSTON SV300S3
Total Size : 57241 MB
SSD : Yes
Device #2
Device is a Hard drive
Reported Channel,Device(T:L) : 0,8(8:0)
Vendor :
Model : TOSHIBA THNSNJ51
Total Size : 488386 MB
SSD : Yes
Device #3
Device is a Hard drive
Reported Channel,Device(T:L) : 0,9(9:0)
Vendor : HITACHI
Model : HUS156060VLS600
Total Size : 572325 MB
SSD : No
Device #4
Device is a Hard drive
Reported Channel,Device(T:L) : 0,10(10:0)
Vendor : HITACHI
Model : HUS156060VLS600
Total Size : 572325 MB
SSD : No
Device #5
Device is a Hard drive
Reported Channel,Device(T:L) : 0,11(11:0)
Vendor : HITACHI
Model : HUS156060VLS600
Total Size : 572325 MB
SSD : No
Device #6
Device is a Hard drive
Reported Channel,Device(T:L) : 0,12(12:0)
Vendor :
Model : TOSHIBA THNSNJ51
Total Size : 488386 MB
SSD : Yes
Device #7
Device is a Hard drive
Reported Channel,Device(T:L) : 0,13(13:0)
Vendor : HITACHI
Model : HUS156060VLS600
Total Size : 572325 MB
SSD : No
Device #8
Device is a Hard drive
Reported Channel,Device(T:L) : 0,14(14:0)
Vendor : HITACHI
Model : HUS156060VLS600
Total Size : 572325 MB
SSD : No
Device #9
Device is a Hard drive
Reported Channel,Device(T:L) : 0,15(15:0)
Vendor : HITACHI
Model : HUS156060VLS600
Total Size : 572325 MB
SSD : No
Device #10
Device is a Hard drive
Reported Channel,Device(T:L) : 0,16(16:0)
Vendor :
Model : TOSHIBA THNSNJ51
Total Size : 488386 MB
SSD : Yes
Device #11
Device is a Hard drive
Reported Channel,Device(T:L) : 0,17(17:0)
Vendor : HITACHI
Model : HUS156060VLS600
Total Size : 572325 MB
SSD : No
Device #12
Device is a Hard drive
Reported Channel,Device(T:L) : 0,18(18:0)
Vendor : HITACHI
Model : HUS156060VLS600
Total Size : 572325 MB
SSD : No
Device #13
Device is a Hard drive
Reported Channel,Device(T:L) : 0,19(19:0)
Vendor : HITACHI
Model : HUS156060VLS600
Total Size : 572325 MB
SSD : No
Device #14
Device is a Hard drive
Reported Channel,Device(T:L) : 0,20(20:0)
Vendor :
Model : TOSHIBA THNSNJ51
Total Size : 488386 MB
SSD : Yes
Device #15
Device is a Hard drive
Reported Channel,Device(T:L) : 0,21(21:0)
Vendor : HITACHI
Model : HUS156060VLS600
Total Size : 572325 MB
SSD : No
Device #16
Device is a Hard drive
Reported Channel,Device(T:L) : 0,22(22:0)
Vendor : HITACHI
Model : HUS156060VLS600
Total Size : 572325 MB
SSD : No
Device #17
Device is a Hard drive
Reported Channel,Device(T:L) : 0,23(23:0)
Vendor : HITACHI
Model : HUS156060VLS600
Total Size : 572325 MB
SSD : No
Device #18
Device is an Enclosure services device
Reported Channel,Device(T:L) : 2,0(0:0)
Vendor : LSILOGIC
Model : SASX28 A.1
Вывод конфигурации - Логически Диски (RAID массивы)
arcconf getconfig 1 LDarcconf getconfig 1 LD |grep -E "number|name|RAID|Read-cache"
Logical device number 0
Logical device name : SYSTEM
RAID level : 1
Read-cache setting : Enabled
Read-cache status : On
Logical device number 1
Logical device name : SSD1TB
RAID level : 10
Read-cache setting : Disabled
Read-cache status : Off
Logical device number 2
Logical device name : SAS3,6T
RAID level : 10
Read-cache setting : Enabled
Read-cache status : On
Создание RAID массивов
arcconf CREATE 1 LOGICALDRIVE NAME SAS3,6T Rcache RON Wcache WBB MAX 10 0 9 0 10 0 11 0 13 0 14 0 15 0 17 0 18 0 19 0 21 0 22 0 23CREATE 1 - создать на контроллере 1
NAME SAS3,6T - имя массива
Rcache RON - кэш на чтение - включена
Wcache WBB - кэш на запись - включена
MAX - использовать всё имеющееся пространство
10 - RAID10
0 9 0 10 0 11 0 13 0 14 0 15 0 17 0 18 0 19 0 21 0 22 0 23 - какие диски добавить в массив.
Берётся всё это вот откуда
У каждого диска есть следующие данные
Device #17
Device is a Hard drive
Reported Channel,Device(T:L) : 0,23(23:0)
Vendor : HITACHI
Собственно вы таким образом узнаёте по каждому диски Channel и Device номера и прописываете их с пробелами в строке создания массива
Комментариев нет: